Skip to content

Temperature conversion status bit can sometimes hang #7

Closed
@caternuson

Description

@caternuson

In theory, looping and checking the state of bit 7 in the Status Register (0x02) should work:

image

But there have been a few cases where this bit seems to not update:
https://forums.adafruit.com/viewtopic.php?f=60&t=162020
https://forums.adafruit.com/viewtopic.php?f=60&t=162446
https://forums.adafruit.com/viewtopic.php?f=60&t=162388
and so the wait-for-conversion loop never exists.

Communication with the ADT seems OK otherwise. Can do low level I2C xfers. Can even do a software reset.