@@ -27,17 +27,17 @@ The Arduino Opta® Analog Expansion is designed for industrial standard machiner
2727
## Features
2828
### General Specifications Overview
2929

30-
| Characteristics | Details |
31-
|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
32-
| Supply Voltage | 12...24 V |
33-
| Reverse polarity protection | Yes |
34-
| ESP protection | Yes |
35-
| Transient overvoltage protection | Yes (up to 40 V) |
36-
| Maximum Supported Expansions | Up to 5 |
37-
| Channels | 8x: I1, I2, I3, I4, O1, I5, I6, O2 |
38-
| Channels functionalities | I1 and I2: Programmable inputs (Voltage, Current, RTD2 wires, RTD3 wires), Programmable outputs (Voltage and current) - I3, I4, O1, I5, I6, O2: Programmable inputs (Voltage, Current, RTD2 wires), Programmable outputs (Voltage and current) |
39-
| Degree of Protection | IP20 |
40-
| Certifications | FCC, CE, UKCA, cULus, ENEC |
30+
| Characteristics | Details |
31+
|-------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
32+
| Supply Voltage | 12...24 V |
33+
| Reverse polarity protection | Yes |
34+
| ESP protection | Yes |
35+
| Transient overvoltage protection | Yes (up to 40 V) |
36+
| Maximum Supported Expansion Modules | Up to 5 |
37+
| Channels | 8x: I1, I2, I3, I4, O1, I5, I6, O2 |
38+
| Channels functionalities | I1 and I2: Programmable inputs (Voltage, Current, RTD2 wires, RTD3 wires), Programmable outputs (Voltage and current) - I3, I4, O1, I5, I6, O2: Programmable inputs (Voltage, Current, RTD2 wires), Programmable outputs (Voltage and current) |
39+
| Degree of Protection | IP20 |
40+
| Certifications | FCC, CE, UKCA, cULus, ENEC |
4141

4242
<div style="background-color: #FFFFE0; border-left: 6px solid #FFD700; margin: 20px 0; padding: 15px;">
4343
<strong>Note:</strong> Check the inputs and outputs detailed sections below for more information about the Analog Expansion channels use.

content/hardware/07.opta/opta-family/opta-analog-exp/tech-specs.yml

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -4,7 +4,7 @@ Board:
44
Microcontroller:
55
ID: Renesas R7FA4M1AB3CFM ARM® Cortex®-M4
66
Cortex-M4 core: Up to 48 MHz
7-
Maximum Simultaneous Expansions: 5
7+
Maximum Supported Expansion Modules: 5
88
Input:
99
Configurable digital / analog inputs: 8x
1010
Digital operational range: 0-24 V

content/hardware/07.opta/opta-family/opta-digital-exp/datasheet/datasheet.md

Lines changed: 10 additions & 10 deletions
Original file line numberDiff line numberDiff line change
@@ -38,16 +38,16 @@ Arduino Opta® Expansion is designed for industrial standard machinery control a
3838
## Features
3939
### General Specifications Overview
4040

41-
| Characteristics | Details |
42-
|------------------------------|-------------------------------------------------------------------------------------------------------|
43-
| Supply Voltage | 12...24 V |
44-
| Antipolarity protection | Yes |
45-
| Overvoltage protection | Yes (+20%) |
46-
| Maximum Supported Expansions | Up to 5 |
47-
| Inputs | 16x Digital (0-24 V) / Analog (0-24 V) inputs |
48-
| Outputs | AFX00005: 8x Electromechanical Relays (250 VAC - 6 A), AFX00006: 8x Solid State Relays (24 VDC - 2 A) |
49-
| Degree of Protection | IP20 |
50-
| Certifications | FCC, CE, UKCA |
41+
| Characteristics | Details |
42+
|-------------------------------------|-------------------------------------------------------------------------------------------------------|
43+
| Supply Voltage | 12...24 V |
44+
| Antipolarity protection | Yes |
45+
| Overvoltage protection | Yes (+20%) |
46+
| Maximum Supported Expansion Modules | Up to 5 |
47+
| Inputs | 16x Digital (0-24 V) / Analog (0-24 V) inputs |
48+
| Outputs | AFX00005: 8x Electromechanical Relays (250 VAC - 6 A), AFX00006: 8x Solid State Relays (24 VDC - 2 A) |
49+
| Degree of Protection | IP20 |
50+
| Certifications | FCC, CE, UKCA |
5151

5252
### Inputs
5353

content/hardware/07.opta/opta-family/opta-digital-exp/tech-specs.yml

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -5,7 +5,7 @@ Board:
55
Microcontroller:
66
ID: Renesas R7FA4M1AB3CFM ARM® Cortex®-M4
77
Cortex-M4 core: Up to 48 MHz
8-
Maximum Simultaneous Expansions: 5
8+
Maximum Supported Expansion Modules: 5
99
Input:
1010
Configurable digital / analog input: 16
1111
Digital Operational Range: 0-24 V

content/hardware/07.opta/opta-family/opta/tech-specs.yml

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -21,7 +21,7 @@ Relays:
2121
Maximum current per relay: 10 A
2222
Maximum peak current per relay: 15 A
2323
Connectivity and communication:
24-
Maximum Supported Expansions: Up to 5
24+
Expansion Port: Up to 5 expansion modules (e.g., AFX00005, AFX00006, AFX00007)
2525
USB-C®:
2626
For programming and data logging: All variants
2727
Ethernet:

content/hardware/07.opta/opta-family/opta/tutorials/01.user-manual/content.md

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -2456,7 +2456,7 @@ Here is an example of how to connect a DC load to the Opta Digital Ext D1608S (S
24562456

24572457
![SSR expansion wiring example](assets/ssr-output.png)
24582458

2459-
***The Opta™ controller module can support up to 5 expansion modules. Connecting more than this may result in unexpected behavior. __Ensure the module limit is not exceeded and the Aux connector and clips are properly secured.__***
2459+
***The Opta™ controller module can support up to __5 expansion modules__. Connecting more than this may result in unexpected behavior. __Ensure the module limit is not exceeded and the Aux connector and clips are properly secured.__***
24602460

24612461
You can buy and find more information about the Opta™ Digital Expansions on the links below:
24622462

@@ -4116,7 +4116,7 @@ To fully understand the example above, we recommend you to check the [General Li
41164116

41174117
The function `optaAnalogTask()` turns on sequentially the **LEDs** and turns them off again.
41184118

4119-
***The Opta™ controller module can support up to 5 expansion modules. Connecting more than this may result in unexpected behavior. __Ensure the module limit is not exceeded and the Aux connector and clips are properly secured.__***
4119+
***The Opta™ controller module can support up to __5 expansion modules__. Connecting more than this may result in unexpected behavior. __Ensure the module limit is not exceeded and the Aux connector and clips are properly secured.__***
41204120

41214121
You can buy and find more information about the Opta™ Analog Expansions on the links below:
41224122

0 commit comments

Comments
 (0)